C  O  N  C  E  P  T

GROVE                                                              "distinctive design.... quality craftsmanship"

19 SWEET VERNAL COURT ROCHESTER, NEW YORK 14623                                                       TEL / FAX  (716) 334-1232

 

FRP Specifications;

PART           1.0             GENERAL

                      1.01           RELATED DOCUMENTS:

                                        Drawings and general provisions of the contract.

                      1.02           DESCRIPTION OF WORK:

                                        A.    Provide prefabricated fiberglass reinforced polyester (FRP) shapes for   

                                                architectural purposes.

                                        B.    Work includes, but is not limited to: Restoring and/or sculpting of          

                                                existing ornamentation or new trim; mold making production, molding and

                                                shop fabrication.

                      1.03           RELATED WORK

                                        Specification for structural steel framing for primary support of FRP panels, and joint

                                        sealer at joints between adjacent FRP panels and at perimeter of FRP panels field shall

                                        not be part of this specification.

                      1.04           BUILDING CODE COMPLIANCE:

                                        All work shall conform to building codes by contracting authority.

                      1.05           SYSTEM PERFORMANCE:

                                        A.    The FRP shapes, when installed shall be capable of with standing positive and

                                                negative wind pressure without structural failure, permanent distortion or

                                                displacement.

                                        B.    Allowable design stresses and resistance shall be conservatively selected by the

                                                engineer.

                                        C.    Load Bearing Strengths:  The maximum temporary deflection due to all loads

                                                shall not exceed 1/360 th of the distance between supports.

                                        D.    Thermal Movement:  Design, fabricate and install component parts to provide

                                                for expansion and contraction over an ambient temperature range of 120

                                                degrees without damage.

                      1.06           JOB CONDITIONS;    

                                        Verify dimensions at the job site and adjust final shop drawings and fabricated parts to

                                        actual field measurements.

                      1.07           QUALITY CONTROL:

                                        A.    Fabricator shall institute quality control procedures for manufactures of FRP

                                                units to control color, texture, dimensions, lines surfaces and strength of

                                                materials.

                                        B.    Manufacturer:

                                                1.             Manufacturer shall demonstrate its ability and capacity to produce

                                                                products of the quality and scope of this  project requirements.

                                                2.             Manufacture / Fabricator shall have been actively involved in  

                                                                Architectural FRP Production for a minimum of 5 years.

                                                3.             Acceptable Manufacturer:

                                                                                Concept Grove Inc.

                                                                                19 Sweet Vernal Court

                                                                                Rochester , NY 14623          (716) 334-1232

                                                                Or: Qualified and approved equal.

 

                      1.08           SUBMITTALS:

                                        A.    Shop Drawings

                                                1.             Submit shop drawings complete information for the fabrication and

                                                                installation of FRP units.  Indicate member dimension , and cross-

                                                                section , location , size and type of reinforcement, including special

                                                                reinforcement necessary for handling and erection.

                                                2.             Provide layout , dimensions and identification of each FRP unit

                                                                corresponding to the sequence and procedure of installation.  Indicate

                                                                location and details of anchoring devices that are to e embedded in

                                                                other construction.

                                                3.             Samples: Submit two sets of samples (approx. 6" x 6")  to illustrate

                                                                quality , color, and texture of finished surfaces.  Approved samples

                                                                shall becomes the standard for judging the work.

PART           2.0            MATERIAL

                      2.01           SURFACE:

                                        A.    The molded exterior surface of the FRP units shall consist of UV inhibited,

                                                sanitary grade NPG-ISO polyester gel coat w/ silica sand broad cast.

                                        B.    Wet gel coat film thickness should be 18 to 22 mils thick.

                                        C.    Gel coat shall be color matched to sample provided.

                      2.02           BACK UP LAMINATE

                                        A.    Resin

                                                1.             Isophthallic Polyester resin.

                                                2.             Standard GP

                                        B.    Fiberous Glass Reinforcement

                                                1.             "E" type fiberglass.

                                                2.             Random chopped glass fiber.

                                                3.             Glass content approx. 25% to 30%

                                        C.    Laminate Thickness.           

                                                1.             Nominal thickness approx. 3/16" typ.                             

                                                2.             Additional thickness and reinforcement, and sandwich structures used

                                                                where necessary for structural strength.

                      2.03           AVERAGE MECHANICAL PROPERTIES:

                                        PROPERTY                   VALUE                  TEST METHOD

                                        Tensile strength          12,000 PSI                              ASTM D638

                                        Flexural  strength         18,000 PSI                              ASTM D790

                                        Flexural  modulus         0.9 x 10  to 6th PSI                ASTM D790

                                        Compressive strength 18,000 PSI                              ASTM  D695

                                        Bearing strength          10,000 PSI                              ASTM  D638

                                        Thermal expansion       10 x 10 to -6th                        (in/in/F)

                                        Weight / surface area  1 PSF     

                                        NOTE: Certain applications may be best suited  to specialty resin not capable of meeting

                                        the above mechanical strengths values.  Such resin will be allowed with compensatory

                                        increases in minimum thickness.

                      2.04           RELATED MATERIALS:

                                        Attachment and / or  hanging structures (supplies by others)  shall be of stainless steel,

                                        galvanized steel or treated wood blocking.

                                        All  hardware (supplied by installers) shall be galvanized or stainless steel.


 

PART 3.0     EXECUTION

                      3.01           INSTALLATION: (By installation contractor)

                                        A.    Lift, place and secure FRP units in accordance with Mfgr's  shop drawings

                                                and as acceptable to Architect.

                                        B.    Protect units from damage from field operation.

                                        C.    Caulk all joints with approved elastomeric sealant.

                                        D.    Assure conformity of all as -built structural and attachment substrate     

                                                dimensions to the allowable tolerances for proper  installation of prefabricated

                                                architectural FRP components.

                                        E.     Coordinate delivery and installation of FRP components with the work of other

                                                trades.

                                        F.     Confirm the acceptance of all underlying  structural and / or attachments

                                                substrates prior to allowing installation of architectural FRP component s to

                                                proceed.

                                        G.    Do not allow work involving the use of resin based materials to proceed at

                                                temperatures below 55 degree F.

                      3.02           WARRANTY

                                        A.    The minimum acceptable warranty provision for architectural FRP components

                                                shall be:

                                                1.             All fabrication will be in accordance with approved drawings and

                                                                specifications.

                                                2.             Materials and workmanship will meet or surpass industry standards

                                                                for similar work.

                                                3.             Any components found to be defective in materials or workmanship

                                                                will be either repaired or replaced at the option of the fabricator.

                                                4.             The minimum warranty period will be twelve (12) months following

                                                                substantial completion.

                      3.03           ADJUSTMENTS AND CLEANING

                                        A.    Repair (in accordance with manufacturers written procedures) and /        

                                                or removed and replaced any damaged or defective FRP components.

                                        B.    Clean exposed surfaces of FRP components soiled during the work for this

                                                section.

                                        C.    Clean up all debris resulting from the work of this section.

                      3.04           INSPECTION AND ACCEPTANCE

                                        A.    Final inspection and acceptance of erection FRP panels shall be made by

                                                the Architect and or owner to verify conformance with plans and specifications.